Isto irá apagar a página "1. BENCHMARK_ISOTHERMAL". Por favor, certifique-se.
python3 -m thermal_event_simulator validate benchmark --scenario BENCHMARK_ISOTHERMAL_1
BENCHMARK Validation Results Summary:
Processed: 1 scenarios
Successful: 1 scenarios
Average Score: 100.0/100
Score Range: 100.0 - 100.0
Execution Time: 0.47 seconds
================================================================================
📊 BENCHMARK VALIDATION SUMMARY - 1 scenarios
================================================================================
📈 Total Scenarios: 1
✅ Successful Validations: 1
🎯 Average Validation Score: 100.0/100
🏆 Assessment Distribution: Excellent(1), Very Good(0), Good(0), Acceptable(0)
============================================================================================================================================================================================================================
🔧 COMPREHENSIVE SCENARIO CONFIGURATION SUMMARY
============================================================================================================================================================================================================================
CHAMBER CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Volume Room Temp Amb Press Geometry Mix Eff Shape CF
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 1.0m³ 20°C 1.0bar sphere 1.0 1.0
GAS RELEASE CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Gas Vol Gas Temp Release Time Vol Cond Gas Fractions
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 **100L 20°C** 1.0s stp N2:1.000 (norm)
EXHAUST SYSTEM CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Tube Len Tube Diam Discharge C Friction F Filter Eff Circuit
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 0.0m 0.001m 0.00 0.000 1.00 open
VENTILATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Dilution ACH Ramp Time Leak Cd Leak Area Inlet Pos Outlet Pos
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 0.0 0.0s 0.000 0.000 unknown unknown
WALL THERMAL CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Wall Mass Cp Conductance UA Out
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 0kg 0J/kgK 0.0W/K 0.0W/K
SIMULATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Sim Time Exp Thresh Scenario Name Geom Effects
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 5s 0.0bar benchmark_isot No
====================================================================================================================================================================================
🔍 VALIDATION RESULTS SUMMARY
====================================================================================================================================================================================
Scenario Name Score Assessment Metric Calculated Expected Deviation Tolerance Within Tol
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_20°C/100L 100.0 EXCELLENT peak_pressure_bar 1.120 1.122 -0.1% ±1.5% ✅ PASS
peak_temperature_c 20.0°C 20.0°C +0.0°C ±0.1°C ✅ PASS
BENCHMARK_ISOTHERMAL_20°C/500L 99.3 EXCELLENT peak_pressure_bar 1.594 1.603 -0.5% ±1.5% ✅ PASS
peak_temperature_c 45.0°C 45.0°C +0.0°C ±0.1°C ✅ PASS
🎉 OVERALL ASSESSMENT: OUTSTANDING - Models demonstrate exceptional accuracy!
✅ Thermal Event Simulator completed successfully!
BENCHMARK Validation Results Summary:
Processed: 1 scenarios
Successful: 1 scenarios
Average Score: 99.2/100
Score Range: 99.2 - 99.2
Execution Time: 0.52 seconds
================================================================================
📊 BENCHMARK VALIDATION SUMMARY - 1 scenarios
================================================================================
📈 Total Scenarios: 1
✅ Successful Validations: 1
🎯 Average Validation Score: 99.2/100
🏆 Assessment Distribution: Excellent(1), Very Good(0), Good(0), Acceptable(0)
============================================================================================================================================================================================================================
🔧 COMPREHENSIVE SCENARIO CONFIGURATION SUMMARY
============================================================================================================================================================================================================================
CHAMBER CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Volume Room Temp Amb Press Geometry Mix Eff Shape CF
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 1.0m³ 100°C 1.0bar sphere 1.0 1.0
GAS RELEASE CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Gas Vol Gas Temp Release Time Vol Cond Gas Fractions
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 **500L 100°C** 1.0s stp N2:1.000 (norm)
EXHAUST SYSTEM CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Tube Len Tube Diam Discharge C Friction F Filter Eff Circuit
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 0.0m 0.001m 0.00 0.000 1.00 open
VENTILATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Dilution ACH Ramp Time Leak Cd Leak Area Inlet Pos Outlet Pos
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 0.0 0.0s 0.000 0.000 unknown unknown
WALL THERMAL CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Wall Mass Cp Conductance UA Out
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 0kg 0J/kgK 0.0W/K 0.0W/K
SIMULATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name Sim Time Exp Thresh Scenario Name Geom Effects
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 5s 0.0bar benchmark_isot No
====================================================================================================================================================================================
🔍 VALIDATION RESULTS SUMMARY
====================================================================================================================================================================================
Scenario Name Score Assessment Metric Calculated Expected Deviation Tolerance Within Tol
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1 99.2 EXCELLENT peak_pressure_bar 1.695 1.705 -0.6% ±1.5% ✅ PASS
peak_temperature_c 100.0°C 100.0°C +0.0°C ±0.1°C ✅ PASS
🎉 OVERALL ASSESSMENT: OUTSTANDING - Models demonstrate exceptional accuracy!
✅ Thermal Event Simulator completed successfully!
Isto irá apagar a página "1. BENCHMARK_ISOTHERMAL". Por favor, certifique-se.