1. BENCHMARK_ISOTHERMAL
kk laboja lapu 2 mēneši atpakaļ
python3 -m thermal_event_simulator validate benchmark --scenario BENCHMARK_ISOTHERMAL_1
BENCHMARK Validation Results Summary:
Processed: 1 scenarios
Successful: 1 scenarios
Average Score: 100.0/100
Score Range: 100.0 - 100.0
Execution Time: 0.47 seconds
================================================================================
📊 BENCHMARK VALIDATION SUMMARY - 1 scenarios
================================================================================
📈 Total Scenarios: 1
✅ Successful Validations: 1
🎯 Average Validation Score: 100.0/100
🏆 Assessment Distribution: Excellent(1), Very Good(0), Good(0), Acceptable(0)

============================================================================================================================================================================================================================
🔧 COMPREHENSIVE SCENARIO CONFIGURATION SUMMARY
============================================================================================================================================================================================================================
CHAMBER CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Volume     Room Temp    Amb Press    Geometry     Mix Eff    Shape CF  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              1.0m³      20°C         1.0bar       sphere       1.0        1.0       

GAS RELEASE CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Gas Vol    Gas Temp     Release Time   Vol Cond   Gas Fractions       
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              **100L       20°C**         1.0s           stp        N2:1.000 (norm)     

EXHAUST SYSTEM CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Tube Len   Tube Diam    Discharge C  Friction F   Filter Eff   Circuit   
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              0.0m       0.001m       0.00         0.000        1.00         open      

VENTILATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Dilution ACH   Ramp Time    Leak Cd    Leak Area    Inlet Pos    Outlet Pos  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              0.0            0.0s         0.000      0.000        unknown      unknown     

WALL THERMAL CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Wall Mass    Cp         Conductance    UA Out    
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              0kg          0J/kgK     0.0W/K         0.0W/K    

SIMULATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Sim Time   Exp Thresh   Scenario Name   Geom Effects  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              5s         0.0bar       benchmark_isot  No            

====================================================================================================================================================================================
🔍 VALIDATION RESULTS SUMMARY
====================================================================================================================================================================================
Scenario Name                       Score    Assessment   Metric             Calculated   Expected     Deviation      Tolerance    Within Tol  
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_20°C/100L              100.0    EXCELLENT    peak_pressure_bar  1.120        1.122        -0.1%          ±1.5%        ✅ PASS      
                                                          peak_temperature_c 20.0°C       20.0°C       +0.0°C         ±0.1°C       ✅ PASS      
BENCHMARK_ISOTHERMAL_20°C/500L              99.3     EXCELLENT    peak_pressure_bar  1.594        1.603        -0.5%          ±1.5%        ✅ PASS      
                                                          peak_temperature_c 45.0°C       45.0°C       +0.0°C         ±0.1°C       ✅ PASS 

🎉 OVERALL ASSESSMENT: OUTSTANDING - Models demonstrate exceptional accuracy!

✅ Thermal Event Simulator completed successfully!

BENCHMARK Validation Results Summary:
Processed: 1 scenarios
Successful: 1 scenarios
Average Score: 99.2/100
Score Range: 99.2 - 99.2
Execution Time: 0.52 seconds
================================================================================
📊 BENCHMARK VALIDATION SUMMARY - 1 scenarios
================================================================================
📈 Total Scenarios: 1
✅ Successful Validations: 1
🎯 Average Validation Score: 99.2/100
🏆 Assessment Distribution: Excellent(1), Very Good(0), Good(0), Acceptable(0)

============================================================================================================================================================================================================================
🔧 COMPREHENSIVE SCENARIO CONFIGURATION SUMMARY
============================================================================================================================================================================================================================
CHAMBER CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Volume     Room Temp    Amb Press    Geometry     Mix Eff    Shape CF  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              1.0m³      100°C        1.0bar       sphere       1.0        1.0       

GAS RELEASE CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Gas Vol    Gas Temp     Release Time   Vol Cond   Gas Fractions       
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              **500L       100°C**        1.0s           stp        N2:1.000 (norm)     

EXHAUST SYSTEM CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Tube Len   Tube Diam    Discharge C  Friction F   Filter Eff   Circuit   
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              0.0m       0.001m       0.00         0.000        1.00         open      

VENTILATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Dilution ACH   Ramp Time    Leak Cd    Leak Area    Inlet Pos    Outlet Pos  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              0.0            0.0s         0.000      0.000        unknown      unknown     

WALL THERMAL CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Wall Mass    Cp         Conductance    UA Out    
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              0kg          0J/kgK     0.0W/K         0.0W/K    

SIMULATION CONFIGURATION:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Scenario Name                       Sim Time   Exp Thresh   Scenario Name   Geom Effects  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              5s         0.0bar       benchmark_isot  No            


====================================================================================================================================================================================
🔍 VALIDATION RESULTS SUMMARY
====================================================================================================================================================================================
Scenario Name                       Score    Assessment   Metric             Calculated   Expected     Deviation      Tolerance    Within Tol  
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
BENCHMARK_ISOTHERMAL_1              99.2     EXCELLENT    peak_pressure_bar  1.695        1.705        -0.6%          ±1.5%        ✅ PASS      
                                                          peak_temperature_c 100.0°C      100.0°C      +0.0°C         ±0.1°C       ✅ PASS      

🎉 OVERALL ASSESSMENT: OUTSTANDING - Models demonstrate exceptional accuracy!

✅ Thermal Event Simulator completed successfully!